Universidad Autónoma de Chile
  • Admisión
  • Universidad
  • Vinculación con el Medio
  • Investigación
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
  • Investigación
  • Proyectos
  • Personas
  • Estadísticas
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Investigación y Desarrollo
  3. Publicaciones
  4. Accuracy in body composition scanning by adult half-body DXA scanning
 
  • Detalles
Options

Accuracy in body composition scanning by adult half-body DXA scanning

Fecha de emisión
2023
Autor(es)
Gómez-Campos, Rossana
Vidal Espinoza, Rubén
Moreira Goncalves, Ezequiel
David Langer, Raquel
Borges, Juliano Henrique
Castelli Correia de Campos, Luis Felipe
Urra Albornoz, Camilo
Facultad de Educación 
Sulla Torres, José
Cossio-Bolaños, Marco
DOI
10.20960/nh.04416
Resumen
Introduction: dual-energy X-ray absorptiometry (DXA) is the gold standard method, although one limitation is the size of the scan area. Objective: the objective was to verify the accuracy of body composition (BC) scanning through half-body DXA scanning compared to standard total body scanning. Methods: a study was conducted on 145 volunteers. Weight and height were assessed. Body mass index (BMI) was calculated. DXA was used for whole-body scan (WBS) and half-body scan (HBS). WBS was used as the reference method and the following indicators were extracted: bone mineral content (BMC), fat mass (FM), lean soft tissue (LST) and percentage fat mass (%FM). Results: no differences were observed in the body composition indicators (BMC, FM, LST and %FM) when compared between the reference WBS scanner and the HBS scanner. The predictive power between both scans ranged in both sexes between R2 = 0.94 and 0.98. The DRI desirable reproducibility index values defining the degree of agreement between both scans ranged from 0.97 to 0.99, and the values for precision (0.97 to 0.99) and accuracy (0.99) were high. Conclusion: HBS scanning by DXA evidenced agreement, and high values of accuracy and precision to assess body composition indicators (BMC, FM, LST and %FM). © 2023 SENPE and Arán Ediciones S.L.
Temas
  • Accuracy

  • Adult

  • Body composition

  • DXA

Archivo(s)
Loading...
Thumbnail Image
Download
Name

MA0441602.pdf

Size

1017.7 KB

Format

Checksum
Contáctanos
  • Comunícate con nosotros

    Ir al formulario
  • Denuncias de convivencia, acoso laboral y sexual

    Ingresa aquí
Sedes y Campus
  • Providencia, Santiago
  • El Llano Subercaseaux, Santiago
  • Talca
  • Temuco
Universidad
  • Acreditación 2024
  • Vicerrectoría Académica
  • Vicerrectoría de Aseguramiento de la Calidad
  • Vicerrectoría de Investigación y Doctorados
  • Vicerrectoría de Vinculación con el Medio
  • Facultades
  • Dirección de Desarrollo y Postgrados
  • Dirección General de Vida Universitaria y Comunicaciones
Comunicaciones corporativas
  • Noticias
  • Eventos
  • Redes sociales
Información y servicios
  • Calendario Académico
  • Clínicas de Atención Psicológica
  • Clínicas Jurídicas y Sociales
  • Institutos de Investigación
  • Centros de Investigación
  • Políticas, Reglamentos y Protocolos
  • Pagos en línea
  • Verificación de Certificados
  • Términos Legales y Condiciones Generales
  • Convenios Recursos Públicos
  • TOP3-UNIV-JOVENES
  • 2DO-CITAS-INVESTIGACION
  • times-high-ed-caluga-web-nueva
  • UNIV-SALUD-PUBLICA
  • TOP10-SCIMAGO
  • CNA
  • AQAS
  • ANECA
  • ADSCRITA

©2024 | Universidad Autónoma de Chile