Mostrar el registro sencillo del ítem

dc.contributor.authorSanhueza, Mario I.
dc.contributor.authorCastillo, Rosario del P.
dc.contributor.authorMeléndrez, Manuel F.
dc.contributor.authorvon Plessing, Carlos G.
dc.contributor.authorTereszczuk, Joanna
dc.contributor.authorOsorio, Germán
dc.contributor.authorPeña-Farfal, Carlos
dc.contributor.authorFernández, Marcos J.
dc.contributor.authorNeira, José Yamil
dc.date.accessioned2021-06-22T16:00:08Z
dc.date.available2021-06-22T16:00:08Z
dc.date.issued2021-09
dc.identifier10.1016/j.microc.2021.106479
dc.identifier.issn0026265X
dc.identifier.urihttps://hdl.handle.net/20.500.12728/8939
dc.description.abstractConfocal laser scanning microscopy (CLSM) supported with multivariate analysis is proposed as hyperspectral imaging technique to identify, locate, and quantify, in a direct way, active pharmaceutical ingredients (APIs) in synthetic tablets, with the aim of establishing a new analysis methodology that collects qualitative and quantitative information from the surface and inner layers of solid dosage forms. This method is proposed as a novel, non-destructive, rapid, and highly sensitive hyperspectral imaging technique, with an excellent spatial resolution at the microscopic level. Two chemical systems comprising pharmaceutical mixtures of acetaminophen–caffeine–excipients and digoxin–excipients were analyzed by multivariate curve resolution-alternating least squares (MCR-ALS) using emission spectra obtained from microscopic images with the pixel sizes of 512 μm × 512 μm to localize the APIs in the tablets. In addition, partial least squares (PLS) regression models were developed and used for calibration to obtain the concentration of the fluorescent active ingredients. The analysis by MCR-ALS delivered excellent results in localizing the fluorescent compounds; meanwhile, PLS achieved good error parameters for prediction of the external validation set for the quantification of caffeine and less successful quantification of digoxin. The performance of CLSM was evaluated by estimation of the analytical figures of merit of the technique to assess the quantification of APIs, including calculations of the uncertainty in the signal, sensitivity, analytical sensitivity, and ranges of detection and quantification limits. Use of CLSM as hyperspectral imaging attempts to increase the application of this technique in direct analysis of solid samples, showing that autofluorescent compounds can be analyzed for qualitative and quantitative purposes in presence of interferents by application of chemometrics.es_ES
dc.language.isoenes_ES
dc.publisherElsevier Inc.es_ES
dc.subjectConfocal laser scanning microscopyes_ES
dc.subjectHyperspectral imaginges_ES
dc.subjectMultivariate image regressiones_ES
dc.subjectSolid dosage formses_ES
dc.titleConfocal laser scanning microscopy as a novel tool of hyperspectral imaging for the localization and quantification of fluorescent active principles in pharmaceutical solid dosage formses_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem