Mostrar el registro sencillo del ítem

dc.contributor.authorLopez-Arce P.
dc.contributor.authorAltamirano-Medina H.
dc.contributor.authorBerry J.
dc.contributor.authorRovas D.
dc.contributor.authorSarce F.
dc.contributor.authorHodgson S.
dc.date.accessioned2020-09-02T22:21:47Z
dc.date.available2020-09-02T22:21:47Z
dc.date.issued2020
dc.identifier10.1007/s12273-020-0680-8
dc.identifier.issn19963599
dc.identifier.urihttps://hdl.handle.net/20.500.12728/5099
dc.descriptionThe occurrence of surface condensation and mould can lead to concerns of poor indoor air quality and adverse health implications of occupants. Remedial actions require identification of the root causes, but this can be challenging even for experts. The focus of the research is the development of a diagnostic tool that helps to streamline root cause analysis. The diagnostic method comprises a protocol with guidelines for installation of sensors, easy data collection, and a set of calculations to process environmental information. Environmental parameters collected and calculated from an environmental monitoring exercise of dwellings with and without mould, include physical properties associated with the indoor surface of external walls and surrounding air conditions. The methodology relies on linking specific surface and air environmental parameters together with critical thresholds proposed for the control and avoidance of surface condensation and mould growth in dwellings. These parameters were assessed and used to determine the likely causal factors of a moisture imbalanced environment leading to surface condensation and mould growth; poor thermal building envelope performance, an imbalanced heat-moisture regime, and/or insufficient ventilation. Examples from different scenarios are presented to show the process towards environmental data collection, post-processing to compute and assess pertinent parameters, and the display of environmental conditions in a clear and easy-to-interpret manner. The novel developed system is a time-saving method for processing and represents environmental data. It provides a straightforward building moisture index (BMI) and a systematic diagnostic procedure for environmental assessment and possible causes of mould growth. This helps to support neutral decision making, to identify rectification strategies and direct to more cost-efficient solutions to existing damp and mould problems in buildings. © 2020, The Author(s).
dc.language.isoen
dc.publisherTsinghua University Press
dc.subjectbuildings
dc.subjectcondensation
dc.subjectdiagnosis
dc.subjectenvironmental monitoring
dc.subjectmoisture
dc.subjectmould growth
dc.subjectAir quality
dc.subjectCondensation
dc.subjectDecision making
dc.subjectHousing
dc.subjectIndoor air pollution
dc.subjectMoisture
dc.subjectMolds
dc.subjectDiagnostic procedure
dc.subjectEnvironmental assessment
dc.subjectEnvironmental conditions
dc.subjectEnvironmental information
dc.subjectEnvironmental Monitoring
dc.subjectEnvironmental parameter
dc.subjectHealth implications
dc.subjectSurface condensation
dc.subjectData acquisition
dc.titleBuilding moisture diagnosis: Processing, assessing and representation of environmental data for root cause analysis of mould growth
dc.typeArticle


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem