Mostrar el registro sencillo del ítem

dc.contributor.authorHerráiz-Adillo Á.
dc.contributor.authorSoriano-Cano A.
dc.contributor.authorMartínez-Hortelano J.A.
dc.contributor.authorGarrido-Miguel M.
dc.contributor.authorMariana-Herráiz J.Á.
dc.contributor.authorMartínez-Vizcaíno V.
dc.contributor.authorNotario-Pacheco B.
dc.date.accessioned2020-09-02T22:20:29Z
dc.date.available2020-09-02T22:20:29Z
dc.date.issued2018
dc.identifier10.1080/08037051.2017.1400903
dc.identifier.citation27, 2, 112-119
dc.identifier.issn08037051
dc.identifier.urihttps://hdl.handle.net/20.500.12728/4891
dc.descriptionPurpose: Inter-arm systolic blood pressure differences (IASBPD) and inter-leg systolic blood pressure differences (ILSBPD) have arisen as potential tools to detect peripheral artery disease (PAD) and individuals at high cardiovascular risk. This study aims to evaluate the diagnostic accuracy of IASBPD and ILSBPD to detect PAD, and whether IASBPD or ILSBPD improves diagnostic accuracy of the oscillometric ankle-brachial index (ABI). Materials and methods: In this prospective study, eligible for inclusion were consecutive adults, with at least one of the following cardiovascular risk factors: diabetes, dyslipidemia, hypertension, smoking habit or age ≥65. IASBPD, ILSBPD and ankle-brachial index (ABI) were measured in all participants through four-limb simultaneous oscillometric measurements and compared with Doppler ABI (reference test, positive cut-off: ≤ 0.9). Results: Of 171 subjects included, PAD was confirmed in 23 and excluded in 148. Thirteen and 38 subjects had IASBPD and ILSBPD ≥10 mmHg, respectively. Pearson correlation with Doppler ABI of IASBPD and ILSBPD was 0.073 (P =.343) and −0.628 (P <.001), respectively. Diagnostic accuracy of an ILSBPD ≥10 mmHg to detect PAD was: sensitivity = 69.6% (95%CI = 48.6–90.5), specificity = 85.1% (79.1–91.2), diagnostic odds ratio (dOR) = 13.1 (4.8–35.5) and area under ROC curve (AUC) = 0.765 (0.616–0.915). IASBPD had an AUC = 0.532 (0.394–0.669), and oscillometric ABI had an AUC = 0.977 (0.950–1.000). The addition of ILSBPD to oscillometric ABI reduced dOR from 174.0 (38.3–789.9) to 34.4 (9.5–125.1). Similarly, the addition of IASBPD reduced dOR to 49.3 (14.6–167.0). Conclusions: In a Primary Care population with ≥1 cardiovascular risk factors, ILSBPD showed acceptable diagnostic accuracy for PAD, whilst IASBPD accuracy was negligible. However, the combination of ILSBPD (or IASBPD) with oscillometric ABI did not improve the ability to detect PAD. Thus, oscillometer ABI seems to be preferable to detect PAD and individuals at high cardiovascular risk. ILSBPD could be uniquely recommended for the diagnosis of PAD when blood pressure measurements in upper limbs are not possible. © 2017 Informa UK Ltd, trading as Taylor & Francis Group.
dc.language.isoen
dc.publisherTaylor and Francis Ltd
dc.subjectAnkle-brachial index
dc.subjectblood pressure
dc.subjectinter-arm systolic blood pressure difference
dc.subjectinter-leg systolic blood pressure difference
dc.subjectperipheral artery disease
dc.subjectsensitivity
dc.subjectspecificity
dc.subjectaged
dc.subjectankle brachial index
dc.subjectArticle
dc.subjectcardiovascular risk
dc.subjectcontrolled study
dc.subjectdiabetes mellitus
dc.subjectdiagnostic accuracy
dc.subjectdiagnostic test accuracy study
dc.subjectDoppler ultrasonography
dc.subjectdyslipidemia
dc.subjectfalse negative result
dc.subjectfalse positive result
dc.subjectfemale
dc.subjecthigh risk patient
dc.subjecthuman
dc.subjecthypertension
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectoscillometry
dc.subjectperipheral occlusive artery disease
dc.subjectpredictive value
dc.subjectpriority journal
dc.subjectprospective study
dc.subjectsensitivity and specificity
dc.subjectsmoking
dc.subjectsystolic blood pressure
dc.subjectblood pressure
dc.subjectperipheral occlusive artery disease
dc.subjectphysiology
dc.subjectsystole
dc.subjectblood pressure
dc.subjectblood pressure measurement
dc.subjectleg
dc.subjectperipheral occlusive artery disease
dc.subjectAged
dc.subjectAnkle Brachial Index
dc.subjectBlood Pressure
dc.subjectFemale
dc.subjectHumans
dc.subjectMale
dc.subjectPeripheral Arterial Disease
dc.subjectProspective Studies
dc.subjectSystole
dc.subjectBlood Pressure
dc.subjectBlood Pressure Determination
dc.subjectLeg
dc.subjectPeripheral Arterial Disease
dc.subjectSystole
dc.titleSimultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study
dc.typeArticle


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem