Mostrar el registro sencillo del ítem
Reliability and validity of measuring scale for postoperative complications in third molar surgery
dc.contributor.author | Aravena P.C. | |
dc.contributor.author | Astudillo P. | |
dc.contributor.author | Miranda H. | |
dc.contributor.author | Manterola C. | |
dc.date.accessioned | 2020-09-02T22:12:22Z | |
dc.date.available | 2020-09-02T22:12:22Z | |
dc.date.issued | 2018 | |
dc.identifier | 10.1186/s12903-018-0486-6 | |
dc.identifier.citation | 18, 1, - | |
dc.identifier.issn | 14726831 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12728/3580 | |
dc.description | Background: Third molar removal surgery is the most frequently performed surgery in the oral and maxillofacial field with a wide range of items in the quantification of postoperative complications. For their measure, in 2014 a previous scale design was presented. The aim of this study was to determine the reliability and validity of a scale designed to measure and quantify postoperative complications in third molar surgery (TMS). Methods: A cross-sectional study of a measurement model was designed. Sixty-two patients (mean age 20.5±6.6years; 36 women) underwent TMS in three Chilean hospitals. In the postoperative check-up on the 7th day, a maxillofacial surgeon and a surgical resident performed independent postoperative assessments, applying the scale. A confirmatory factor analysis was conducted to obtain validity, internal consistency, interobserver reliability and a score to categorize the severity of complications using structural equation model analysis. Results: Nine patients (14.5%) had complications. The scale was defined by two components: "Secondary complication" and "Infection" (Cronbach's alpha 0.71; Interobserver reliability 87.7%) and three categories of postoperative complication: "without or mild", "moderate" and "severe". Conclusion: This study presents a reliability and validity scale called "Surgical complication assessment scale in TMS". © 2018 The Author(s). | |
dc.language.iso | en | |
dc.publisher | BioMed Central Ltd. | |
dc.subject | Measurement scale, factor analysis | |
dc.subject | Oral surgery | |
dc.subject | Postoperative complications | |
dc.subject | Third molar | |
dc.subject | cross-sectional study | |
dc.subject | factor analysis | |
dc.subject | female | |
dc.subject | human | |
dc.subject | male | |
dc.subject | observer variation | |
dc.subject | postoperative complication | |
dc.subject | reproducibility | |
dc.subject | surgery | |
dc.subject | third molar | |
dc.subject | tooth extraction | |
dc.subject | young adult | |
dc.subject | Cross-Sectional Studies | |
dc.subject | Factor Analysis, Statistical | |
dc.subject | Female | |
dc.subject | Humans | |
dc.subject | Male | |
dc.subject | Molar, Third | |
dc.subject | Observer Variation | |
dc.subject | Postoperative Complications | |
dc.subject | Reproducibility of Results | |
dc.subject | Tooth Extraction | |
dc.subject | Young Adult | |
dc.title | Reliability and validity of measuring scale for postoperative complications in third molar surgery | |
dc.type | Article |