Mostrar el registro sencillo del ítem

dc.contributor.authorMarinelli, Franco
dc.contributor.authorVenegas, Camila
dc.contributor.authorRuiz, Joaquin Victorio
dc.contributor.authorFarfán-Beltrán, Nicole
dc.contributor.authorStaub, Erwin
dc.contributor.authorNavarro, Pablo
dc.contributor.authorAlarcón-Apablaza, Josefa
dc.contributor.authorFuentes, Ramón
dc.date.accessioned2024-06-21T20:22:06Z
dc.date.available2024-06-21T20:22:06Z
dc.date.issued2024
dc.identifier10.3390/bioengineering11030229
dc.identifier.issn23065354
dc.identifier.urihttps://hdl.handle.net/20.500.12728/11551
dc.description.abstractEdentulism can generate negative impacts on self-esteem, interpersonal relationships, and oral functions. Removable prostheses are commonly used for tooth replacement, but they may cause discomfort due to micromovements during mastication. Objective and quantifiable methods are needed to evaluate these micromovements. A pilot study was conducted to determine the micromovements in removable prostheses during mastication using a 3D electromagnetic articulography (EMA-3D) system. One elderly participant wearing lower removable prostheses and an upper total well-fitting removable prosthesis was studied. The EMA-3D system was used to record movements in three spatial planes. Peanuts were given as test food, and the participant was instructed to chew normally while recordings were carried out until feeling the need to swallow. Analyses of the upper total prosthesis show micromovements ranging from 0.63 ± 0.11 to 1.02 ± 0.13 mm. During simultaneous analyses of the upper prosthesis and lower partial prosthesis, interference was not observed. This pilot study demonstrated the feasibility of using the EMA-3D system to evaluate micromovements in removable prostheses during mastication. Further research is needed to evaluate a larger sample and assess the clinical implications of these micromovements. © 2024 by the authors.es_ES
dc.description.sponsorshipUniversidad de La Frontera, UFRO, (PAT22-0006)es_ES
dc.language.isoenes_ES
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)es_ES
dc.subjectchewinges_ES
dc.subjectedentulismes_ES
dc.subjectelectromagnetic articulographyes_ES
dc.subjectmasticationes_ES
dc.subjectmicromovementses_ES
dc.subjectremovable prostheseses_ES
dc.titleDetermination of Micromovements in Removable Prosthesis during Mastication: A Pilot Study with 3D Electromagnetic Articulographyes_ES
dc.typeArticlees_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem